Fire Doors

How much does fire door installation cost?

A fitted FD30 fire door typically costs from around £1,600 + VAT for a new leaf in a sound existing frame, and around £3,000 + VAT for a complete doorset with frame, leaf and ironmongery. FD60, double, glazed and steel doors cost more and are priced from measurements. We give a fixed price from photos.

By Sebastian Grabowski, DC Fire & Security, Luton. Updated November 2026.

Your options

The first question is whether the frame can stay. A fire door is a tested assembly of leaf, frame, seals, hinges and closer, so a new leaf only works in a frame that is sound and suitable for it.

OptionWhen it suitsWhat you get
New leaf in the existing frameThe frame is sound and certified or suitableA new FD30 leaf hung, adjusted and certified in your frame
Complete doorsetThe frame is damaged, missing or not certifiedFrame, leaf, standard ironmongery, seals and closer, supplied and installed
Premium or specified doorsetYou want a veneered or prefinished door, upgraded ironmongery, vision panelsA door specified to match the building, with a concealed closer or drop seal if needed

FD60 doors, double doors, glazed doors and steel doors are priced from your measurements. Send photos and the number of doors and we confirm which options apply. Our guides on supply and fit costs and glazed fire doors go into the detail, and steel against timber covers the material choice.

Why the installation matters as much as the door

A fire door performs as tested only when the whole assembly matches the test evidence. Approved Document B says the evidence must apply to the complete installed assembly, and that small differences in detail can significantly affect the rating. A certified leaf hung badly in an unsuitable frame is not a fire door.

What the fitter has to get right:

  • The frame fixed solidly, with the gap to the wall packed and sealed so smoke cannot track round it
  • Even gaps all round, set when the door is hung, not planed in afterwards
  • The right hinges, a full set of screws, and a closer that shuts and latches the door from any angle
  • Intumescent strips and smoke seals in the correct profile and position, and not painted over
  • Glazing, locks, letterplates and viewers that suit the door, from kits tested for it
  • Signs and a label so the next inspector can see what the door is

A leaf alone is not a doorset, and a blank or a cut-down door can look right and still fail because nothing proves the assembly was tested. If you are weighing a bought-in blank against a certified doorset, read fire-rated doorsets against door blanks.

What decides the price

  • Leaf only or complete doorset. Keeping a sound frame saves the frame, the fixing and the making good round it.
  • FD30 or FD60. The higher rating usually means a thicker, heavier door, bigger seals and stronger ironmongery.
  • Size and type. Doubles, oversized leaves and fanlights cost more than a standard single door.
  • Glazing. A vision panel needs fire-rated glass and beads tested with that door.
  • Ironmongery. A concealed closer, drop seal or electric hold-open costs more than a surface closer.
  • Finish. Veneered and prefinished leaves cost more than a paint-grade door.
  • How many doors. A run of identical doors across a building is cheaper per door than one.
  • Access and making good. Occupied flats, out-of-hours working and the state of the wall round an old frame all take time.

A plain certified doorset is our advice for nearly every job. Panels, mouldings and period trim cut into a leaf can void its fire rating, so we do not add them, and a panelled design is only possible where the manufacturer certifies that exact door.

How an installation runs

1. Send photos of the doors and frames, or your inspection report, with the number of doors and the postcode. 2. We confirm what can be kept and what needs replacing, and give a fixed price per door with the options explained. 3. A deposit books the date, and the date is confirmed once it clears. Lead times depend on the door and are confirmed with the price. 4. The doors are fitted by our BM TRADA / FIRAS-certificated contractors, each one adjusted and checked, and photographed. 5. You get the certificates and photo record for your fire safety file.

The doorsets themselves carry third-party certification. DC supplies, specifies and manages the work, and the certificate for the fitting comes from the contractors who do it.

Repair or replace

Many failed doors can be repaired for far less than a new door, so read fire door repairs and repair or replace a failed fire door before you order. An inspection will tell you which doors really need replacing. Flat entrance doors in blocks are covered in flat entrance fire door replacement, and doors in shared areas in communal fire door replacement.

Who we install for

Blocks of flats (flat entrance and communal doors), schools and colleges, care homes, offices, shops and industrial units, HMOs and landlords, and housing associations.

Where we install

We are based in Luton and fit fire doors across Bedfordshire, Hertfordshire, Buckinghamshire, London, the Thames Valley and the East Midlands. Local pages: Luton, Milton Keynes, Bedford, Watford, St Albans, Hemel Hempstead, Stevenage, Reading, London, Harrow, Oxford and Cambridge. Not listed? Send the postcode. Choosing between installers is covered in how to choose fire door installers.

Related guides

Sources

Frequently Asked Questions

What is the difference between FD30 and FD60?
The number is the minutes of fire resistance, measured as integrity, that the tested door assembly gives: FD30 for at least 30 minutes and FD60 for at least 60. FD30 is the usual choice for flat entrance and many internal doors, and FD60 is used where the wall or floor around the door needs more.
Can you fit a new door into my existing frame?
Often, if the frame is sound and suitable, and we check it from photos. If the frame is damaged, missing or not suitable for the new leaf, a complete doorset is the safer option.
Are your fire doors certified?
Yes. Doors are third-party certified and installed by our BM TRADA / FIRAS-certificated contractors, with the certificates provided for your records.
Does fitting include signage and the paperwork?
Yes. Doors are signed where required, and each one is photographed, with a record and the certificates for your fire safety file.
Can I have a panelled or period-style fire door?
Only if the manufacturer certifies that exact design as a doorset. Cutting panels or mouldings into a fire door, or adding them later, can void its rating, so we advise a plain certified doorset and price a panelled design only if you ask.
Can you supply and fit a single fire door for a flat or house?
Yes. We supply and fit single fire doors for flats and houses, as well as larger numbers for schools, offices and blocks, including doors that failed an inspection. Every door is a third-party certificated product, fitted to BS 8214 and the manufacturer's instructions. You get the certification details and a photo record when it is done.
Can a fire door have glazing or a panelled design?
Yes, within limits. Glazed fire doors are fine when the glass and beads are part of the door's certification. A panelled look is only possible where the manufacturer certifies that exact design as a doorset. We never cut panels or add mouldings to a fire door, because that can void its rating. Our usual advice is a plain certified doorset.
Does my flat entrance door have to be an FD30S fire door?
In most blocks of flats and converted houses, yes. A flat entrance door opening onto a shared corridor or stair should be a self-closing fire door, usually FD30S, to protect the escape route. The building's fire risk assessment states what is required. If your existing door is a genuine fire door in good order, a repair may be enough instead of a replacement.
Will a new fire door come with certificates and installation paperwork?
Yes. You get the doorset's certification details, a record of the installation and before and after photos. The door is a third-party certificated product fitted to the manufacturer's instructions, which is what an independent inspector checks against. Where an installation certificate under a third-party scheme is required, the work goes to our third-party certificated contractors.
What information do you need to quote for a new fire door?
Send the full height and width of the opening and the existing door, its thickness, photos of both faces and the frame, which way it opens, and any hardware you need, such as a letterplate, viewer or particular lock. Tell us if the building requires a set style or colour. With that we can price it without a visit.
Can you fit certified fire doors to risers, cupboards and plant rooms?
Yes. Riser, cupboard and plant room doors are often FD30 or FD60 and are usually kept locked shut rather than self-closing. We supply and fit certified doorsets for them, with suitable locks and fire door signs. Send photos, sizes and any fire strategy or fire risk assessment reference, and we price each door.
How long does it take to fit a new fire door?
Fitting a complete doorset usually takes most of a day per door, including taking out the old one, fitting, adjusting, testing and photos. A new leaf in an existing frame is quicker. On larger jobs we plan several doors across the days so the building stays usable throughout.
Can I keep my existing door frame when fitting a new fire door?
Sometimes. If the frame is sound, fire rated and the right size, a new leaf can be hung in it, which costs less than a full doorset. If the frame is damaged, not rated, or the gaps cannot be brought within limits, a complete doorset is the better answer. Photos of the frame and its edges usually tell us which.
Can a new fire door have particular locks, closers or seals?
Yes, as long as each item is compatible with the door's certification. Thumb-turn locks, overhead or concealed closers, smoke seals and drop-down seals are all available for fire doors. Tell us what you need when you ask for the price and we include certified hardware that suits the door.
Do I need permission from the freeholder or managing agent to replace my fire door?
Usually, yes. In most leasehold flats the entrance door is part of the building's fire protection, and the lease often requires consent before it, or its hardware, is changed. Check your lease and ask for any specification the building requires, such as colour or hardware, before ordering. We can quote to that specification.
How do I compare fire door installation quotes?
Check that every quote is for a third-party certificated doorset, not just a fire-rated leaf, and that it includes the frame, hinges, closer, seals, removal of the old door and the paperwork. Cheaper quotes often leave out the frame or the certification. Our price is fixed for a compliant, certified door, so you know the total before we start.
What fire doors and fire alarm does an HMO need, and can you quote both?
An HMO usually needs self-closing fire doors on bedrooms and the kitchen onto the escape route, plus a linked fire alarm, but the council's licence conditions and the fire risk assessment set the exact requirement. We do both, so we can price the doors and the alarm together. Send the licence conditions or FRA, photos and a floor plan.

Send us photos or your report

Email your report or photos to info@dcsecurity.co.uk, or use the form. We usually come back with a fixed price the same day. Luton, Bedfordshire, Hertfordshire, Buckinghamshire and London.

Request a free quote

Send photos for a fixed price · No obligation · Response within 24 hours