We do, from Luton, across the whole county. We fit and service commercial and communal fire alarm systems to BS 5839-1:2017, including retrofits in older town-centre buildings and shared systems in blocks of flats. Where walls and ceilings cannot be opened up, we use a wireless system. A service visit on a small system starts from about £400 + VAT.
Most Hertfordshire buildings that need an alarm already exist. Fitting into them is a different job from a new build.
Market towns such as St Albans, Hertford, Hitchin and Bishop's Stortford have historic centres. Shops, pubs, offices and flats sit over each other in buildings that were converted more than once. The cable route, the ceiling height and the walls are all decided by what is already there.
We survey first, plan device positions on a marked-up plan, and tell you what is hidden before the first cable goes in. If your alarm is more than a decade old and the panel is no longer supported, see when to replace a fire alarm system.
A radio system sends signals between devices without running cable through the fabric.
In a listed building, drilling, chasing and ceiling work can damage the very features that give the building its status. Altering a listed building usually needs listed building consent from the council's conservation team, so ask them before any fixings go in. A wireless system keeps the work small, reversible and easier to agree.
Wireless is still a BS 5839-1 system. It must be designed for the category you need, with battery life, radio signal strength and the loss of a device all planned and tested at commissioning. It is not a cheap-looking domestic kit on the wall. Read our guides to alarms for listed buildings, wireless fire alarms and wired versus wireless.
Churches and community halls are common in the county's villages and old centres. Fire alarms for churches and heritage buildings covers the detector choices that suit tall roofs and timber.
Commuter-belt blocks, converted offices and new builds each raise a different question.
In a purpose-built block with a stay-put strategy, the flats usually have their own detection and the common parts are protected by smoke control, fire doors and, where the design calls for it, a communal system. Whether the building needs a communal alarm comes from its fire strategy and the fire risk assessment. Our guide do flats need fire alarms in communal areas explains how that decision is made.
The communal system sits alongside the doors. A fire alarm does not replace the flat entrance doors or the compartment walls, and a fire door inspection is a separate job. Buying guidance for managing agents is in fire alarms for blocks of flats.
BS 5839-1 uses L categories for life protection and P categories for property protection.
Your fire risk assessment decides the category, not the installer's preference. Escape-route-only cover is L3, wider cover is L2 and full coverage is L1. An office usually sits at L2 or L3, and a building with sleeping risk is normally designed higher. Our page on alarm categories sets this out, and what BS 5839 says covers the standard.
If you do not have an assessment, we recommend one first. See fire risk assessments in Hertfordshire. An alarm designed without one can be the wrong size for the building.
An alarm fitted once and forgotten is a liability.
Emergency lighting goes in the same visit where it is needed. Our emergency lighting guide covers BS 5266-1.