Fire Extinguisher Types: Which One Fights Which Fire, and What Your Premises Needs

By the DC Fire & Security engineering team — installing and maintaining fire and security systems since 2010. Updated July 2026.

SSAIB CCTV, Intruder Alarm & Access Control Certificated
Fast Response Times
15+ Years Experience
500+ Commercial Clients

Quick answer

There are six extinguisher types in UK use: water (ordinary solids), water mist (the flexible newcomer — most solid and liquid fires, many rated for electrical), foam (solids plus flammable liquids), dry powder (the outdoor generalist — solids, liquids, gases, electrical, but a nightmare indoors), CO2 (electrical equipment and liquids, no residue), and wet chemical (the only proper answer to cooking-oil fires). Most workplaces need just two of them: the classic pairing is foam (or water) plus CO2 on every floor, with wet chemical added in kitchens and powder where vehicles or gases live.

The six types against the six fire classes

TypeFire classesStrengthsNever use on
WaterA (wood, paper, textiles)Cheap, effective soak on solids, no chemical residueElectrical, flammable liquids, cooking oil
Water mistA, some B and F ratings; many models tested for live electrical to 1,000VOne-cylinder-covers-most flexibility, minimal damage, no chemicalsCheck the label per model — ratings vary more than any other type
Foam (AFFF)A and B (petrol, solvents, paints)Smothers liquid fires, re-ignition barrierCooking oil; treat electrical as off-limits unless dielectrically tested
Dry powder (ABC)A, B, C (gases); safe on electricalThe broadest coverage and the choice outdoors, on vehicles, LPG, plantEnclosed spaces if avoidable — visibility loss, inhalation, wrecks electronics; never fryers
CO2B and electricalZero residue — the server-room and office standard alongside foamClass A solids (re-ignites), confined spaces; never grip the horn
Wet chemicalF (cooking oils/fats) and AThe only type designed for deep-fat fryer fires — cools and seals the oilClass B liquids, electrical unless label states otherwise

Ratings: what 13A and 55B on the label mean

Every extinguisher carries a fire rating — 13A, 21A, 55B, 75F — which is the size of test fire it extinguished in certification. The number scales with capability, the letter is the fire class: a 21A water unit kills a bigger wood-crib fire than a 13A; a 144B foam handles a larger liquid tray than a 55B. This is the number that matters when comparing units — a 'big red extinguisher' with a small rating is theatre.

Ratings are also how provision is calculated. The benchmark from BS 5306-8 works out at a combined 26A per floor as the starting point for ordinary Class A risk (scaled to floor area) — which in practice means two 13A-rated extinguishers per floor as the familiar minimum. Your fire risk assessment does this arithmetic against your actual layout; the extinguisher colours guide covers identifying what's already on your walls.

The standard combinations that cover real premises

  • Office floor — foam 13A + CO2 by the exits: solids covered, electricals covered, no residue disasters in the server cupboard
  • Commercial kitchen — wet chemical within reach of the fryers + fire blanket + CO2 for the electrics; staff trained that water never enters the equation
  • Warehouse / workshop — foam or water for the racking and packaging, CO2 at the charging stations, powder where LPG trucks or vehicles operate
  • Construction site — powder's home turf: mixed fuels, outdoors, vehicles and temporary electrics
  • Landlord common parts — often minimal or none by design: in many blocks the strategy is evacuation, not amateur firefighting, and the fire risk assessment decides — not the catalogue
  • Server / comms rooms — CO2 only; powder in a server room is a total-loss event even for a small fire

Water mist and lithium: the two modern wrinkles

Water mist deserves its growing popularity: de-ionised water as a fine mist, rated across solid fires, many liquid fires and often live electrical to 1,000V, leaving near-zero damage. For mixed-risk premises wanting to simplify to one type on the wall, it's the one to price — with the caveat that ratings vary sharply by model and size, so the label does the deciding, not the category.

Lithium-ion batteries — e-bikes, scooters, power tools — are the fastest-growing fire risk in UK buildings, and none of the six standard types properly extinguishes a battery in thermal runaway. Specialist lithium agents exist and the market is maturing; until it settles, the honest controls are prevention (charging rules, no escape-route charging, storage) and early detection. If your premises has an e-bike habit, your fire risk assessment should already say so.

Servicing is the same regardless of type: annual basic service to BS 5306-3, extended service at five years (ten for CO2), and a service label that proves it — covered in more depth in the colours guide.

Related guides

Frequently Asked Questions

What are the 5 main types of fire extinguisher?
Water, foam, dry powder, CO2 and wet chemical — with water mist increasingly counted as a sixth. Each maps to fire classes: water and foam for solids (foam adds liquids), powder for the broadest range including gases, CO2 for electrical, wet chemical for cooking oils.
Which fire extinguisher is used for electrical fires?
CO2 is the standard; dry powder also covers electrical where the label shows the pictogram, and many water-mist models are tested on live equipment to 1,000V. Standard water and foam stay away from electrics — and killing the power first is always move one when it's safe.
What is a 13A fire extinguisher?
The rating, not the size: it extinguished a 1.3-metre standard wood-crib test fire in certification. Ratings are how BS 5306-8 calculates provision — the common floor minimum works out at 26A combined, hence the familiar pair of 13A units.
Can I use a fire extinguisher on a chip pan fire?
Only wet chemical — it's designed to cool and seal burning oil. Water, foam or powder into hot oil ranges from useless to explosive. At home, a fire blanket and a closed door beat any wrong extinguisher.
How many fire extinguishers do I need in my business?
Set by your fire risk assessment: the baseline is Class A cover per floor (26A combined as the benchmark, scaled to area, within 30m travel distance), CO2 alongside electrical risk, and specialist types where the risks exist — wet chemical for fryers, powder for vehicle and gas areas.
Do you sell or service fire extinguishers?
No — and that's deliberate, so our advice has no sales agenda. We do the surrounding compliance: fire risk assessments (which specify your extinguisher schedule), fire alarms, fire doors and fire stopping across Bedfordshire, Hertfordshire and North London.

The extinguisher schedule should come from a risk assessment — that's us

We don't sell extinguishers, so there's no upsell in this guide. What we do across Luton, Bedfordshire, Hertfordshire and North London is the compliance around them: fire risk assessments that specify exactly what your premises needs, plus fire alarms, fire doors and fire stopping. If nobody has formally specified your extinguisher cover, start there.